High-resolution timer (HRTIM) RM0440
940/2126 RM0440 Rev 4
The ADC post-scaler programming register are preloaded and can be updated on-the-fly
without stopping the timers.
Figure 253. ADC trigger post-scaling in up-counting mode
Figure 254. ADC trigger post-scaling in up/down counting mode
MSv47427V1
ADCxPSC[4:0]=0
Counter
ADCxPSC[4:0]=1
ADCxPSC[4:0]=2
ADCxPSC[4:0]=3
ADCxPSC[4:0]=4
MSv47428V1
ADCxPSC[4:0]=0
ADROM[1:0]=00
Counter
ADCxPSC[4:0]=1
ADROM[1:0]=01
ADCxPSC[4:0]=1
ADROM[1:0]=10
ADCxPSC[4:0]=3
ADROM[1:0]=00
ADCxPSC[4:0]=4
ADROM[1:0]=01
ADCxPSC[4:0]=4
ADROM[1:0]=10

Table of Contents