EasyManua.ls Logo

ZyXEL Communications MSC1000G - Diagnostic Commands

ZyXEL Communications MSC1000G
1168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 23 diagnostic Commands
Management Switch Card User’s Guide
701
23.4 diagnostic Commands
Use these commands to execute a specified diagnostic or test function to an interface port or a
subscriber port.
23.4.1 diagnostic cfm loopback Command
Syntax:
diagnostic cfm loopback set <md-name> <ma-name> <ep-id> [target <remote-ep-
id>|<mac>]
where
This enables the MEP port (with the specified MEP ID) in a specified CFM domain to send the LBMs
(Loop Back Messages) to a specified remote end point target.
Specify the MD name, MA name, MEP ID, destination (MEP ID or MAC address) to perform a
loopback test.
relay set <slot-port>
in|out|both|off
Turns the test relay in/out function on/off. 8
relay
show
Displays the current MLT relay status of each
VoIP line card’s ports.
1
oam test <slot-port> <pkt-
number> <pktsize>
Sends OAM loopback test Ethernet frames to a
remote Ethernet device.
8
show <slot-port>
Displays Ethernet OAM loopback test results. 8
selt test <slot-port>
Starts SELT on the port. Single End Loop Test
(SELT) checks the distance to the subscriber’s
location.
This feature is applicable for ALC line and VLC
cards only.
Note: The port must have an open loop. There
cannot be a DSL device, phone, fax
machine or other device connected to the
subscriber’s end of the telephone line.
8
show <slot-port>
Displays the SELT result (such as line type and
loop length).
8
Table 354 diagnostic Commands (continued)
COMMAND DESCRIPTION P
md-name =
The maintenance domain name (length<32).
ma-name =
The maintenance association name (length<16)
ep-id =
The endpoint identifier (1~8191).
remote-ep-id =
The target remote end point identifier (1~8191).
mac =
The target remote end point’s MAC address.