Chapter 29 port Commands
Management Switch Card User’s Guide
825
This command sets the second VLAN tag to add to the packets from the PVC.
The following example adds a VLAN tag (100) to the traffic using the DEFVAL ATM profile on PVC
(
1/33) on port 2 of the line card in slot 3.
29.40.3 port tlspvc show Command
Syntax:
port tlspvc show <slot>|<slot-port>|<slot-port-vpi/vci>
This command displays the TLS settings for the specified slot/port/PVC.
29.41 port vdsl Commands
Use the port vdsl commands to configure the subscriber VDSL ports.
29.41.1 port vdsl alarmprof Command
Syntax:
port vdsl alarmprof <slot-port> <profile>
This command sets the VDSL port(s) to use the specified alarm profile.
29.41.2 port vdsl compatible Command
Syntax:
port vdsl compatible <slot-port> none|adsl2|adsl2+
where
<vid>
=
The VLAN ID the switch adds to the traffic on the PVC. This is the VLAN ID known
in the service provider’s network.
Note: Make sure this VLAN ID is not already used for MVLAN or PAE.
ras> port tlspvc set 3-2-1/33 DEFVAL llc 100 12
ras> port tlspvc show 3-2
pvc type mux pvid pri profile
-------------- ------- ----- ------ ---- -------------------
3-2-1/33 tls llc 100 1 DEFVAL
ras>
none
=
Has the VDSL2 services use their normal frequency band plan.
adsl2
=
Has the VDSL2 services not use the ADSL2 frequency bands to avoid possible interference
with ADSL2 services provided by another device on the same bundle of lines.