Chapter 29 port Commands
Management Switch Card User’s Guide
816
29.29.7 port pvc usratelimit disable Command
Syntax:
port pvc usratelimit disable <slot-port-vpi/vci>
This command deactivates upstream rate limiting on the specified PVC.
29.29.8 port pvc usratelimit set Command
Syntax:
port pvc usratelimit set <slot-port-vpi/vci> <rate>
This command sets the maximum upstream rate (in Kbps) the specified PVC is allowed to use. The
following example sets the maximum PVC upstream rate to 1000 Kbps on port 1 of the line card in
slot 5.
29.29.9 port pvc usratelimit show Command
Syntax:
port pvc usratelimit show <slot>|<slot-port>|<slot-port-vpi/vci>
This command displays upstream rate limiting settings on the specified slots, ports, or PVCs. The
following example shows the PVC rate settings on port 1 of the line card in slot 5.
29.29.10 port pvc vlan Command
Syntax:
port pvc vlan <slot-port-vpi/vci> <vid> <registration> <tag>
where
ras> port pvc usratelimit enable 5-1-0/33
ras> port pvc usratelimit set 5-1-0/33 1000
ras> port pvc usratelimit show 5-1
pvc en rate
-------------- ---- --------------
5-1-0/33 V 1000(kbps)
ras> port pvc usratelimit show 5-1
pvc en rate
-------------- ---- --------------
5-1-0/33 - 1000(kbps)
<slot-port-
vpi/vci>
=
The slot and port(s) and VPI/VCI of the PVC.
<vid>
=
The VLAN ID. Valid parameter range = [1 – 4094].
This must be the VLAN ID of a VLAN that is already configured. The ports
specified in this command must also be set to the fixed status in the VLAN.