Chapter 29 port Commands
Management Switch Card User’s Guide
785
29.7.3 dtpvc mvlan enable command
Syntax:
port dtpvc mvlan enable <slot-port-vpi/vci>
This command turns on MVLAN for the specified DTPVC. The following example turns on MVLAN on
DTPVC 8/35 on port 1 on the line card in slot 3.
29.7.4 dtpvc set command
Syntax:
port dtpvc set <slot-port-vpi/vci> <profile> <mux> <svid> <spri> <cvid> <cpri>
where
This command configures a DTPVC on the specified subscriber port. The following example creates
DTPVC 8/35 on port 1 on the line card in slot 5. It uses the DEFVAL profile, LLC encapsulation, a
service provider VLAN ID of 2, an IEEE priority level of 3 for the service provider VLAN tag, a
customer VLAN ID of 10, and an IEEE priority level of 6 for the customer VLAN tag,
29.7.5 dtpvc show command
Syntax:
port dtpvc show <slot>|<slot-port>
This command displays the DTPVC configuration for the specified subscriber slot or port. The
following example displays the DTPVC configuration for the line card in slot 5.
ras> port dtpvc mvlan enable 5-1-8/35
<profile>
=
Name of an ATM profile.
<mux>
=
Encapsulation method (llc or vcmux).
<svid>
=
SVID refers to the service provider’s VLAN ID (the outer VLAN tag). Enter the
service provider ID (from 1 to 4094) for untagged frames received on this DTPVC.
<spri>
=
Enter the priority level for the service provider’s VLAN ID. "0" is the lowest priority
level and "7" is the highest.
<cvid>
=
CVID refers to the customer VLAN ID (the inner VLAN tag). Enter the customer ID
(from 1 to 4094) for untagged frames received on this DTPVC.
<cpri>
=
Enter the priority level for the customer VLAN ID. "0" is the lowest priority level
and "7" is the highest.
ras> port dtpvc set 5-1-8/35 DEFVAL llc 2 3 10 6
ras> port dtpvc show 5
pvc type mux svid spri cvid cpri m profile
--------------- ---- ----- ---- ---- ---- ---- - ---------------------------
5-1-8/35 dtag llc 2 3 10 6 - DEFVAL