Chapter 29 port Commands
Management Switch Card User’s Guide
830
where
This command configures impulse noise protection settings on a VDSL connection.
The following example sets the upstream noise protection at 1 DMT on traffic on port 5 on the VDSL
card in slot 4.
29.41.9 port vdsl ipqos Command
Syntax:
port vdsl ipqos <slot-port> <profile>
where
This command configures QoS (quality of service) settings on a line card’s port.
The following example sets QoS according to settings configured in the profile named “qosprofile1”
on traffic on port 5 on the VDSL card in slot 4.
29.41.10 port vdsl limitmask set Command
Syntax:
port vdsl limitmask set <slot-port> <limitmask>
<us-inp>
<ds-inp>
=
us-inp, ds-inp: The upstream and downstream impulse noise protection setting.
Input 0~160 to set the DMT level to 0.1 of the input value. For example, an input
value of 10 sets the actual DMT value to 1. Input values 1~4 (0.1~0.4 DMT) are not
valid.
ras> port vdsl inpmin 4-5 us-inp 10
<profile> =
The IP QOS profile specified using the profile ipqos command.
ras> port vdsl ipqos 4-5 qosprofile1