05/2014
2-99
DC SC2020
Troubleshooting
CHAIN 93
Version 1.1
• Damage, contamination by foreign substances of the joining terminal between CRUM PWB of
Toner Cartridge (K) and CRUM of Toner CRUM Connector Assembly (K).
• Uncleanness, dislocation of CRUM PWB of Toner Cartridge (K).
• The Toner Cartridge (K) for improper installation
If no problem is found, replace the following parts in sequence:
• Toner Cartridge (K) (PL 5.1)
• Toner CRUM Connector Assembly (K) (Dispenser Drive (CK)) (PL 5.3)
• DRIVE PWB (PL 18.2)
093-926 Toner K CRUM Data Mismatch
BSD-ON:CH9.6
Detected invalid Authentication Area Data of CRUM of Toner Cartridge (K).
Cause/Action
Remove and reinstall the Toner Cartridge (K) and check for improper installation.
Replace with genuine Toner Cartridge (K) (PL 5.1) if there is no problem after checking.
093-928 Toner K CRUM Data Broken
BSD-ON:CH9.6
Detected inequality in write data and read data of CRUM of Toner Cartridge (K).
Cause/Action
Remove and reinstall the Toner Cartridge (K) and check for improper installation.
Replace Toner Cartridge (K) if there is no problem after checking. (PL 8.1)
093-930 Toner Y Life Over
BSD-ON:CH9.5
Toner Cartridge (Y) has reached its life.
Cause/Action
Replace Toner Cartridge (Y). (PL 5.1)
093-931 Toner M Life Over
BSD-ON:CH9.5
Toner Cartridge (M) has reached its life.
Cause/Action
Replace Toner Cartridge (M). (PL 5.1)
093-932 Toner C Life Over
BSD-ON:CH9.6
Toner Cartridge (C) has reached its life.
Cause/Action
Replace Toner Cartridge (C). (PL 5.1)
093-933 Toner K Life Over
BSD-ON:CH9.6
Toner Cartridge (K) has reached its life.
Cause/Action
Replace the Toner Cartridge (K). (PL 5.1)
093-944 Deve HSG Y Life End
BSD-ON:-
Indicates Deve HSG Y reached its usage limit. (Restrict Print operation)
Cause/Action
Replace the Deve Unit (Y). (PL 5.1)
After replacing, enter CE Mode, go to Printer Diag > Parameter > Life > Deve HSG PV Y and initialize the
Life Counter.
093-945 Deve HSG M Life End
BSD-ON:-
Indicates Deve HSG M reached its usage limit. (Restrict Print operation)