05/2014
6-61
DC SC2020
General
6.3.9 NVM 747_Xfer 2 List
Version 1.1
6.3.9 NVM 747_Xfer 2 List
Table 1 NVM 747_Xfer 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized
747-001 Selected Primary Transfer Normal Output Value Storage
(63 Speed/BW Mode)
0 0 800 Stores the Primary Transfer Standard Output Value selected from
the Environment No. when Primary Transfer Output Control is per-
formed
0.1[A] O O
747-002 Selected Primary Transfer Normal Output Value Storage
(63 Speed/FC Mode)
0 0 800 Stores the Primary Transfer Standard Output Value selected from
the Environment No. when Primary Transfer Output Control is per-
formed
0.1[A] O O
747-003 Selected Primary Transfer Normal Output Value Storage
(126 Speed/BW Mode)
0 0 800 Stores the Primary Transfer Standard Output Value selected from
the Environment No. when Primary Transfer Output Control is per-
formed
0.1[A] O O
747-004 Selected Primary Transfer Normal Output Value Storage
(126 Speed/FC Mode)
0 0 800 Stores the Primary Transfer Standard Output Value selected from
the Environment No. when Primary Transfer Output Control is per-
formed
0.1[A] O O
747-005 Primary Transfer Final Output (63 Speed/BW Mode) 0 0 800 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
0.1[A] O O
747-006 Primary Transfer Final Output (63 Speed/FC Mode) 0 0 800 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
0.1[A] O O
747-007 Primary Transfer Final Output (126 Speed/BW Mode) 0 0 800 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
0.1[A] O O
747-008 Primary Transfer Final Output (126 Speed/FC Mode) 0 0 800 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
0.1[A] O O
747-009 Primary Transfer Final Output Digital Value (63 Speed/BW
Mode)
0 0 255 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
<Digital Value> (63 Speed/BW Mode)
-OO
747-010 Primary Transfer Final Output Digital Value (63 Speed/FC
Mode)
0 0 255 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
<Digital Value> (63 Speed/FC Mode)
-OO
747-011 Primary Transfer Final Output Digital Value (126 Speed/BW
Mode)
0 0 255 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
<Digital Value> (126 Speed/BW Mode)
-OO
747-012 Primary Transfer Final Output Digital Value (126 Speed/
FCW Mode)
0 0 255 Stores the Primary Transfer Final Output Value when Primary
Transfer Output Control is performed
<Digital Value> (126 Speed/FC Mode)
-OO
747-013 Secondary Transfer Resistance Detection I Monitor Result
(Average Value Calculation Result)
0 0 4000 Stores the I Monitor Result (average value calculation result) when
Resistance Detection is performed
0.1[A] O O
747-014 Secondary Transfer System Resistance Calculation Result 0 0 1000 Secondary Transfer System Resistance Calculation Result when
Resistance Detection is performed
1[MO] O O
747-015 Selected Secondary Transfer Slant Coefficient: An (Side1) 0 0 255 Selected Secondary Transfer Slant Coefficient: An (Side1) [X1] - O O
747-016 Selected Secondary Transfer Slant Coefficient: An (Side2) 0 0 255 Selected Secondary Transfer Slant Coefficient: An (Side2) [X1] - O O
747-017 Selected Secondary Transfer Segment Coefficient: Bn