EasyManuals Logo

Fuji Xerox DocuCentre SC2020 Service Manual

Fuji Xerox DocuCentre SC2020
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
05/2014
2-90
DC SC2020
CHAIN 91
Version 1.1
Troubleshooting
Cause/Action
Prepare a new Drum Cartridge (M) as the replacement time of the Drum Cartridge (M) is approaching. In
addition, replace the Drum Cartridge (M) as necessary. (PL 8.1)
091-431 Drum Cartridge C Near Life
BSD-ON:CH9.2
The replacement time of the Drum Cartridge (C) is approaching than Pre Near.
Cause/Action
Replace the Drum Cartridge (K) as necessary as the replacement time of the Drum Cartridge (K) is
approaching. (PL 8.1)
091-436 Drum Cartridge C Pre Near Life
BSD-ON:CH9.2
It is necessary to prepare for Drum Cartridge (C) replacement.
Cause/Action
Prepare a new Drum Cartridge (C) as the replacement time of the Drum Cartridge (C) is approaching. In
addition, replace the Drum Cartridge (C) as necessary. (PL 8.1)
091-480 Drum Cartridge Y Life Over
BSD-ON:CH9.1
It is time to replace the Drum Cartridge (Y).
Cause/Action
Replace the Drum Cartridge (Y). (PL 8.1)
091-481 Drum Cartridge M Life Over
BSD-ON:CH9.1
It is time to replace the Drum Cartridge (M).
Cause/Action
Replace the Drum Cartridge (M). (PL 8.1)
091-482 Drum Cartridge C Life Over
BSD-ON:CH9.2
It is time to replace the Drum Cartridge (C).
Cause/Action
Replace the Drum Cartridge (C). (PL 8.1)
091-910 Waste Toner Box Detached
BSD-ON:CH9.12
Detected Waste Toner Bottle is not installed.
Cause/Action
Install the Waste Toner Bottle.
If the problem persists, check the following:
Malfunction of Waste Toner Bottle Full Switch (Digital Input[091-200]). (PL 8.1)
Deformation, defective alignment of Waste Toner Bottle, uncleanness of detection part.
If no problem is found, replace the following parts in sequence:
DRIVE PWB (PL 18.2)
ESS PWB (PL 18.2)
091-911 Waste Toner Bottle Full
BSD-ON:CH9.12
Detected fill Waste Toner Bottle.
Cause/Action
Replace the Waste Toner Container. (PL 8.1)
If the problem persists, check the following:
Malfunction of Waste Toner Bottle Full Switch (Digital Input[091-200]). (PL 8.1)
Deformation, defective alignment of Waste Toner Bottle, uncleanness of detection part.
If no problem is found, replace the following parts in sequence:
DRIVE PWB (PL 18.2)
ESS PWB (PL 18.2)
091-913 Drum Cartridge K Life End
BSD-ON:CH9.2
Indicates that it is time to replace Drum Cartridge (K). (Restrict Print operation)
Cause/Action
Replace the Drum Cartridge (K). (PL 8.1)
091-914 Drum CRUM K Communication Fail

Table of Contents

Other manuals for Fuji Xerox DocuCentre SC2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Xerox DocuCentre SC2020 and is the answer not in the manual?

Fuji Xerox DocuCentre SC2020 Specifications

General IconGeneral
BrandFuji Xerox
ModelDocuCentre SC2020
CategoryAll in One Printer
LanguageEnglish

Related product manuals