7.3 BSD
Chain10 Fusing and Copy Transportation
ABCDEFGHJ
1
2
3
4
5
6
7-54
DRIVE PWB
PL18.2
DRIVE
PWB
PL18.2
10.3 FUSING HEAT CONTROL (2 OF 2)
j0bs731003
FUSING UNIT
PL7.1
HEAT ROLL
THERMISTOR
J414
11
DC COM
DC COM
(1.2 J2)
HEAT ROLL NC SENSOR
VD SENSED SIGNAL
010-200
Analog Input
DP600S
7
DJ600S
7
DP600S
8
DJ600S
8
J414
10
YEL
YEL
HEAT ROLL NC SENSOR
VC SENSED SIGNAL
010-201
Analog Input
66 12
YEL
14
DC COM
(1.2 J2)
4 4
YEL
DC COM
55 13
YEL
HEAT ROLL
THERMISTOR
SENSED SIGNAL
010-203
Analog Input
(INF.)
(TEMP.)
010-202
Analog Input
(DIFF.)
FAIL CODE
Heat Roll STS Disconnection Fail
+3.3VDC
+3.3VDC
+3.3VDC
BLU
BLU
BLU
BLU
HEAT ROLL NC
SENSOR
P606
3
P607
2
J607
3
P607
1
J607
4
P606
1
2
BLU
STS
SIGNAL
10.2
010-420
Fusing Unit Near End Warning
010-421
Fusing Unit Life Warning
010-420
010-421
010-397(01h)
Heat Roll STS Over Temperature Fail
010-397(02h)
Heat Roll NC Sensor Disconnection Fail
010-397(03h)
Heat Roll NC Sensor Over Temperature Fail
010-397(04h)
Heat Roll Paper Winding Fail
010-397(05h)
Warm Up Time Fail
010-397(06h)
Fusing Unit On Time Fail
010-397(07h)
Heat Roll NC Sensor Differential Amp Fail
010-397(08h)
Fusing Unit Hot Not Ready Return Time Fail
010-397(09h)
Heat Roll NC Sensor Broken Fail
010-397(0Ah)
Heat Roll NC Sensor Broken Fail
010-397(0Bh)
Fusing Unit Cold Not Ready Return Time Fail
010-397(0Ch)
010-397(01h)
010-397(02h)
010-397(03h)
010-397(04h)
010-397(05h)
010-397(06h)
010-397(07h)
010-397(08h)
010-397(09h)
010-397(0Ah)
010-397(0Bh)
010-397(0Ch)