05/2014
2-54
DC SC2020
CHAIN 33
Version 1.1
Troubleshooting
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-767 MMR MN86064 Decode Error
BSD-ON:-
In MMR decode, MN86064 decode error.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-768 AT Move Counter Over
BSD-ON:-
The number of AT Move is 5 or more in one stripe.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-769 JBIG NEWLEN Marker Error
BSD-ON:-
NEWLEN marker undetected.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-770 YD Error
BSD-ON:-
Detect YD error in JBIG data decode.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-771 Abort Marker Error
BSD-ON:-
Detect abort marker error in JBIG data decode.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-772 Undefined Marker Error
BSD-ON:-
Detect undefined marker.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.
• FAX PWB (PL 18.5)
• ESS PWB (PL 18.2)
033-773 BIH Error
BSD-ON:-
BIH error in JBIG data decode.
Cause/Action
Recover after the [OK] or [Close] button is pressed or message is displayed for specified time. Turn the
power off and on to check that the error recurs. Then,update to the latest F/W. If the problem cannot be
solved, replace the following parts in sequence.