05/2014
6-39
DC SC2020
General
6.3.5 NVM 740_IOT Manager List
Version 1.1
6.3.5 NVM 740_IOT Manager List
Table 1 NVM 740_IOT Manager List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized
740-002 Cycle Down Timer for Sheet Empty 7000 0 20000 Cycle down timer for Sheet Empty.
Timer for starting Cycle Down after the machine becomes the Sheet Empty status while
printing.
When Cycle Down starts at abnormal failure or when a stop instruction is issued, Cycle
Down starts immediately without using this timer.
1 [ms] O O
740-006 PAR Receive Timeout Error 0 0 255 No. of Sending Timeouts - O O
740-007 PAR Receive Sequence Bit Error 0 0 255 No. of Sequence Bit errors - O O
740-008 PAR Receive Check Sum Error 0 0 255 No. of Check Sum errors - O O
740-009 PAR Send Error 0 0 255 No. of IOT Resends - O O
740-028 ACS Wait Timer 20 0 255 The maximum activation wait time until a color mode is determined when the ACS stan-
dard switching mode is set.
100 [ms] O O
740-029 ACS BW Plate Count 5 3 255 The B/W Continuous Sheets Threshold Value, which is used to judge if the machine
has switched to the B/W mode when the ACS standard switching mode is set.
Side O O
740-030 ACS Sheet Read Count 3 0 255 The number of look-ahead sheets, which is used to judge if the machine has switched
to the B/W mode when the ACS standard switching mode is set.
Sheet O O
740-033 Normal Smear Countermeasure Switch 0 0 1 Operate in FC Mode without following the instruction from the Controller.
0: OFF, 1: ON
-O X
740-034 Heavyweight1 Type Smear Countermeasure
Switch
0 0 1 Operate in FC Mode without following the instruction from the Controller.
0: OFF, 1: ON
-O X
740-035 HW Heavyweight Type Smear Countermea-
sure Switch
0 0 1 Operate in FC Mode without following the instruction from the Controller.
0: OFF, 1: ON
-O X
740-036 Gloss1 Type Smear Countermeasure
Switch
0 0 1 Operate in FC Mode without following the instruction from the Controller.
0: OFF, 1: ON
-O X
740-037 HW Gloss Type Smear Countermeasure
Switch
0 0 1 Operate in FC Mode without following the instruction from the Controller.
0: OFF, 1: ON
-O X
740-038 Access Detector Selection Switch 0 0 1 Select Execute/Do not execute the Access Detector.
0: Perform (Accept the SC Prestart Marking from the Controller.)
1: Do not perform (Ignore the SC Prestart Marking from the Controller.)
-O X
740-042 Diagnostic Device Data Send Cycle 0 0 12 Send cycle for diagnostic device usage status (Local)
1-12: Send Cycle Time (TIme)
0: Do not send
-O O
740-061 EEPROM Information 0 0 2 2: High, 1: Mid, 0: Low - X X
740-109 Productivity Modification Switch (Heavy-
weight Smear Countermeasure)* This is
valid only for 25-sheet and 35-sheet models.
0 0 1 Change the productivity with Heavyweight Smear Countermeasure.
0: OFF (Do not perform), 1: ON (Perform)
-O X
740-110 Custom Toner Mode Switch History 0 0 1 Custom Toner Mode Entry History - O X