6.3.13 NVM 752_Process Control 1 List
Version 1.1
General
752-153 ADC_Mid_Disp Request Time_Buffer Threshold
Value[YMC]
6600 -32768 200000 Buffer Threshold Value for MidSetup Shortened Performance Deter-
mination
1 [ms] O O
752-154 ADC_Mid_Disp Request Time_Buffer Threshold Value[K] 6600 -32768 200000 Buffer Threshold Value for MidSetup Shortened Performance Deter-
mination
1 [ms] O O
752-155 ADC_End_Disp Request Time_Buffer Threshold
Value[YMC]
6600 -32768 200000 Buffer Threshold Value for EndSetup Shortened Performance Deter-
mination
1 [ms] O O
752-156 ADC_End_Disp Request Time_Buffer Threshold
Value[K]
6600 -32768 200000 Buffer Threshold Value for EndSetup Shortened Performance Deter-
mination
1 [ms] O O
752-157 ADC_TC_Disp Request Time_Buffer Threshold
Value[YMC]
6600 -32768 200000 Buffer Threshold Value for TCSetup Shortened Performance Deter-
mination
1 [ms] O O
752-158 ADC_TC_Disp Request Time_Buffer Threshold Value[K] 6600 -32768 200000 Buffer Threshold Value for TCSetup Shortened Performance Deter-
mination
1 [ms] O O
752-161 ADC_Mid/End Low/High AC Counter[Y] 0 0 255 MidEndSetup Performance Counter during Low->High AC - O O
752-162 ADC_Mid/End Low/High AC Counter[M] 0 0 255 MidEndSetup Performance Counter during Low->High AC - O O
752-163 ADC_Mid/End Low/High AC Counter[C] 0 0 255 MidEndSetup Performance Counter during Low->High AC - O O
752-164 ADC_Mid/End Low/High AC Counter[K] 0 0 255 MidEndSetup Performance Counter during Low->High AC - O O
752-165 High Image Density Band Length 30 0 255 SS Direction Length of HIgh Image Density mm O O
752-166 High Image Density Band Density 85 0 100 High Image Density Band Density % O O
752-167 HIgh Image Density Mixing Panel Length 7 0 255 Panel Length of Mixing Cycle in HIgh Image Density 100[mm] O O
752-168 K Color Mixture Prevention Band Length 160 0 255 Length of SS Direction of K Color Mixture Prevention Band mm O O
752-169 K Color Mixture Prevention Band Density 100 0 100 K Color Mixture Prevention Band Density % O O
752-170 K Color Mixture Prevention Band PV[YMC] 0 0 65535 PV to determine creating K Color Mixture Band - O O
752-171 K Color Mixture Prevention Band PV[K] 0 0 65535 PV to determine creating K Color Mixture Band - O O
752-172 K Color Mixture Prevention Band Determination PV
Threshold Value
5000 0 65535 PV Threshold Value to determine creating K Color Mixing Band - O O
752-173 K Color Mixture Prevention Band Determination Ratio
Threshold Value
1000 0 65535 Ratio Threshold Value for determine creating K Color Mixture Pre-
vention Band
-OO
752-174 Vdeve Upper Limit Band Length 120 0 255 SS Direction Length of Vdeve Upper Limit Band mm O O
752-175 Vdeve Upper Limit Band Density 100 0 100 Vdeve Upper Limit Band Density % O O
752-176 Vdeve Upper Limit Band Threshold Value 10 1 255 Vdeve Upper Limit Band Threshold Value - O O
752-177 Vdeve Upper Limit Band ICDC Mean Threshold Value1 20 0 65535 ICDC Mean Threshold Value for creating Vdeve Upper Limit Band - O O
752-178 Vdeve Upper Limit Band ICDC Mean Threshold Value2 15 0 65535 ICDC Mean Threshold Value for creating Vdeve Upper Limit Band - O O
752-179 Delta PR Film Decrease Amount Threshold Value_Vdeve
Upper Limit Band
250 0 1023 PR Film Decrease Amount Threshold Value for creating Vdeve
Upper Limit Band
0.1[m] O O
752-180 Paper Size 0 0 4 0: A4L/Letter/A4S type, 1: B4S type, 2: A3/"17/"19 type, 3: Long
Length1 type, 4: Long Length2 type
-OO
752-181 Screen PV[Copy][YMC] 0 0 4294967295 Screen Individual PV count - O O
752-182 Screen PV[Copy][K] 0 0 4294967295 Screen Individual PV count - O O
752-183 Screen PV[Print2 Value][YMC] 0 0 4294967295 Screen Individual PV count - O O
752-184 Screen PV[Print2 Value][K] 0 0 4294967295 Screen Individual PV count - O O
Table 1 NVM 752_Process Control 1 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized

Table of Contents