EasyManua.ls Logo

Fuji Xerox DocuCentre SC2020 - Page 507

Fuji Xerox DocuCentre SC2020
832 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
05/2014
6-109
DC SC2020
General
6.3.13 NVM 752_Process Control 1 List
Version 1.1
752-394 Delta RADC_Tone_Target Manual Correction Amount
[K][Patch1]
0 -1024 1023 Manual Correction Amount of RADC_Tone_Standard Target Value - O O
752-395 Delta RADC_Tone_Target Manual Correction Amount
[K][Patch2]
0 -1024 1023 Manual Correction Amount of RADC_Tone_Standard Target Value - O O
752-396 Delta RADC_Tone_Target Manual Correction Amount
[K][Patch3]
0 -1024 1023 Manual Correction Amount of RADC_Tone_Standard Target Value - O O
752-397 Delta RADC_Tone_Target Manual Correction Amount
[K][Patch4]
0 -1024 1023 Manual Correction Amount of RADC_Tone_Standard Target Value - O O
752-398 Delta RADC_TC_Target Manual Correction Amount [Y] 0 -1024 1023 The manual Correction amount for RADC_TC Reference Target
Value
-OO
752-399 Delta RADC_TC Target Manual Correction Amount [M] 0 -1024 1023 The manual Correction amount for RADC_TC Reference Target
Value
-OO
752-400 Delta RADC_TC_Target Manual Correction Amount [C] 0 -1024 1023 The manual Correction amount for RADC_TC Reference Target
Value
-OO
752-401 Delta RADC_TC_Target Manual Correction Amount [K] 0 -1024 1023 The manual Correction amount for RADC_TC Reference Target
Value
-OO
752-402 Delta RADC_Potential_Target Manual Correction
Amount[YMC]
0 -128 127 Environment Correction Amount of Potential Control RADC Refer-
ence Target Value
-OO
752-403 Delta RADC_Potential_Target Manual Correction
Amount[K]
0 -128 127 Environment Correction Amount of Potential Control RADC Refer-
ence Target Value
-OO
752-404 Delta RADC_Potential_Target PR Correction Amount [Y] 0 -1024 1023 Delta RADC_Potential_PR Degradation Correction Amount of Target
Value
-OO
752-405 Delta RADC_Potential_Target PR Correction Amount [M] 0 -1024 1023 Delta RADC_Potential_PR Degradation Correction Amount of Target
Value
-OO
752-406 Delta RADC_Potential_Target PR Correction Amount [C] 0 -1024 1023 Delta RADC_Potential_PR Degradation Correction Amount of Target
Value
-OO
752-407 Delta RADC_Potential_Target PR Correction Amount [K] 0 -1024 1023 Delta RADC_Potential_PR Degradation Correction Amount of Target
Value
-OO
752-408 Delta RADC_Tone_Target Environment Correction
Amount [YMC][Patch1]
0 -128 127 Environment Correction Amount of Tone Control RADC Reference
Target Value
-OO
752-409 Delta RADC_Tone_Target Environment Correction
Amount [YMC][Patch2]
0 -128 127 Environment Correction Amount of Tone Control RADC Reference
Target Value
-OO
752-410 Delta RADC_Tone_Target Environment Correction
Amount [YMC][Patch3]
0 -128 127 Environment Correction Amount of Tone Control RADC Reference
Target Value
-OO
752-411 Delta RADC_Tone_Target Environment Correction
Amount [YMC][Patch4]
0 -128 127 Environment Correction Amount of Tone Control RADC Reference
Target Value
-OO
752-412 Delta RADC_Tone_Target Environment Correction
Amount [K][Patch1]
0 -128 127 Environment Correction Amount of Tone Control RADC Reference
Target Value
-OO
752-413 Delta RADC_Tone_Target Environment Correction
Amount [K][Patch2]
0 -128 127 Environment Correction Amount of Tone Control RADC Reference
Target Value
-OO
Table 1 NVM 752_Process Control 1 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized

Table of Contents

Other manuals for Fuji Xerox DocuCentre SC2020

Related product manuals