Version 1.1
752-482 RDP Calculation Value[M] 0 0 65535 RDP Calculation Value - O O
752-483 RDP Calculation Value[C] 0 0 65535 RDP Calculation Value - O O
752-484 RDP Calculation Value[K] 0 0 65535 RDP Calculation Value - O O
752-485 Disp Time for RDP Value Calculation[Y] 0 0 10000000 Disp Time for RDP Value Calculation - O O
752-486 Disp Time for RDP Value Calculation[M] 0 0 10000000 Disp Time for RDP Value Calculation - O O
752-487 Disp Time for RDP Value Calculation[C] 0 0 10000000 Disp Time for RDP Value Calculation - O O
752-488 Disp Time for RDP Value Calculation[K] 0 0 10000000 Disp Time for RDP Value Calculation - O O
752-489 Dmax_IIT Measurement Value[Y] 0 0 1023 IIT Measurement Value for Dmax Correction - O O
752-490 Dmax_IIT Measurement Value[M] 0 0 1023 IIT Measurement Value for Dmax Correction - O O
752-491 Dmax_IIT Measurement Value[C] 0 0 1023 IIT Measurement Value for Dmax Correction - O O
752-492 Dmax_IIT Measurement Value[K] 0 0 1023 IIT Measurement Value for Dmax Correction - O O
752-493 Dmax_IIT Target Value[Y] 0 0 1023 IIT Target Value for Dmax Correction - O O
752-494 Dmax_IIT Target Value[M] 0 0 1023 IIT Target Value for Dmax Correction - O O
752-495 Dmax_IIT Target Value[C] 0 0 1023 IIT Target Value for Dmax Correction - O O
752-496 Dmax_IIT Target Value[K] 0 0 1023 IIT Target Value for Dmax Correction - O O
752-498 Disp Request Time_ICDC[Y] 0 0 32767 Toner Refill Request Time from ICDC Control 1 [ms] O O
752-499 Disp Request Time_ICDC[M] 0 0 32767 Toner Refill Request Time from ICDC Control 1 [ms] O O
752-500 Disp Request Time_ICDC[C] 0 0 32767 Toner Refill Request Time from ICDC Control 1 [ms] O O
752-501 Disp Request Time_ICDC[K] 0 0 32767 Toner Refill Request Time from ICDC Control 1 [ms] O O
752-502 Disp Request Time_Timer [Y] 84 0 10000 Toner Refill Request Time from Timer Control 1 [ms] O O
752-503 Disp Request Time_Timer [M] 90 0 10000 Toner Refill Request Time from Timer Control 1 [ms] O O
752-504 Disp Request Time_Timer [C] 84 0 10000 Toner Refill Request Time from Timer Control 1 [ms] O O
752-505 Disp Request Time_Timer [K] 94 0 10000 Toner Refill Request Time from Timer Control 1 [ms] O O
752-506 Toner Band Disp Request Time [Y] 0 0 32767 Toner Band ICDC Disp Time 1 [ms] O O
752-507 Toner Band Disp Request Time [M] 0 0 32767 Toner Band ICDC Disp Time 1 [ms] O O
752-508 Toner Band Disp Request Time [C] 0 0 32767 Toner Band ICDC Disp Time 1 [ms] O O
752-509 Toner Band Disp Request Time [K] 0 0 32767 Toner Band ICDC Disp Time 1 [ms] O O
752-514 ICDC Coefficient_H[Y] 155 0 65535 High AC ICDC Coefficient - O O
752-515 ICDC Coefficient_H[M] 167 0 65535 High AC ICDC Coefficient - O O
752-516 ICDC Coefficient_H[C] 155 0 65535 High AC ICDC Coefficient - O O
752-517 ICDC Coefficient_H[K] 174 0 65535 High AC ICDC Coefficient - O O
752-518 ICDC Coefficient_L[Y] 155 0 65535 Low AC ICDC Coefficient - O O
752-519 ICDC Coefficient_L[M] 167 0 65535 Low AC ICDC Coefficient - O O
752-520 ICDC Coefficient_L[C] 155 0 65535 Low AC ICDC Coefficient - O O
752-521 ICDC Coefficient_L[K] 174 0 65535 Low AC ICDC Coefficient - O O
752-522 Delta TC Threshold Value_Recovery [Positive][YMC] 21 0 1023 Toner Recovery delta RADC_TC Threshold Value - O O
752-523 Delta TC Threshold Value_Recovery [Positive][K] 21 0 1023 Toner Recovery delta RADC_TC Threshold Value - O O
752-524 Delta TC Threshold Value_Recovery [Positive][YMC] 21 0 1023 Toner Recovery delta RADC_TC Threshold Value - O O
Table 1 NVM 752_Process Control 1 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized

Table of Contents