6.3.15 NVM 755_Process Control 4 List
Version 1.1
755-065 FlagRefill[Y] 0 0 1 0: Normal, 1: Refill - O O
755-066 FlagRefill[M] 0 0 1 0: Normal, 1: Refill - O O
755-067 FlagRefill[C] 0 0 1 0: Normal, 1: Refill - O O
755-068 FlagRefill[K] 0 0 1 0: Normal, 1: Refill - O O
755-069 Flag Installation [Y] 0 0 1 Installation Flag for conducting Toner Conveyance Path Filling
0: Other than Installation Status, 1: Installation Status
-OO
755-070 Flag Installation [M] 0 0 1 Installation Flag for conducting Toner Conveyance Path Filling
0: Other than Installation Status, 1: Installation Status
-OO
755-071 Flag Installation [C] 0 0 1 Installation Flag for conducting Toner Conveyance Path Filling
0: Other than Installation Status, 1: Installation Status
-OO
755-072 Flag Installation [K] 0 0 1 Installation Flag for conducting Toner Conveyance Path Filling
0: Other than Installation Status, 1: Installation Status
-OO
755-073 Flag_NewTonerCTRG[Y] 0 0 1 0: Old Toner Cartridge, 1: New Toner Cartridge - O O
755-074 Flag_NewTonerCTRG[M] 0 0 1 0: Old Toner Cartridge, 1: New Toner Cartridge - O O
755-075 Flag_NewTonerCTRG[C] 0 0 1 0: Old Toner Cartridge, 1: New Toner Cartridge - O O
755-076 Flag_NewTonerCTRG[K] 0 0 1 0: Old Toner Cartridge, 1: New Toner Cartridge - O O
755-077 Flag_TonerCTRG Replacement [Y] 0 0 1 Toner Cartridge Replacement Flag - O O
755-078 Flag_TonerCTRG Replacement [M] 0 0 1 Toner Cartridge Replacement Flag - O O
755-079 Flag_TonerCTRG Replacement [C] 0 0 1 Toner Cartridge Replacement Flag - O O
755-080 Flag_TonerCTRG Replacement [K] 0 0 1 Toner Cartridge Replacement Flag - O O
755-081 Flag Recovery Success [Y] 0 0 1 Flag Recovery Success - O O
755-082 Flag Recovery Success [M] 0 0 1 Flag Recovery Success - O O
755-083 Flag Recovery Success [C] 0 0 1 Flag Recovery Success - O O
755-084 Flag Recovery Success [K] 0 0 1 Flag Recovery Success - O O
755-085 Recovering Flag [Y] 0 0 1 Flag to determine whether the Recovery Operation was completed nor-
mally or not
-OO
755-086 Recovering Flag [M] 0 0 1 Flag to determine whether the Recovery Operation was completed nor-
mally or not
-OO
755-087 Recovering Flag [C] 0 0 1 Flag to determine whether the Recovery Operation was completed nor-
mally or not
-OO
755-088 Recovering Flag [K] 0 0 1 Flag to determine whether the Recovery Operation was completed nor-
mally or not
-OO
755-089 Flag_Toner Indication 0 0 1 Flag to determine the EP Connection (0: UI the Consumable Indication
(No EP Connection), 1: Sensor notify the Consumable Indication (With
EP Connection))
-OO
755-090 No. of MiniSetup_Entry [BW] 0 0 10 Remaining No. of Execution of MiniSetup - O O
755-091 No. of MiniSetup_Entry [FC] 0 0 10 Remaining No. of Execution of MiniSetup - O O
755-092 MiniSetup_No. of Continuous Execution [BW] 0 0 10 No. of Continuous Execution of MiniSetup - O O
755-093 MiniSetup_No. of Continuous Execution [FC] 0 0 10 No. of Continuous Execution of MiniSetup - O O
755-094 PV for creating ADC_Mid/End[YMC] 0 0 65535 PV for determining Mid/EndSetup Patch creation - O O
Table 1 NVM 755_Process Control 4 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized