6.3.18 NVM 761_Deve 1 List
Version 1.1
6.3.18 NVM 761_Deve 1 List
Table 1 NVM 761_Deve 1 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized
761-001 #Y Temperature Raise ICDC Integrated Value 0 0 4294967295 ICDC Integrated Value for Temperature Raise Band [1Count]
Make it 0 when performing ProCon Mid/End Setup.
* ICDC when A4 A/C 100% = 10000
Count O O
761-002 #M Temperature Raise ICDC Integrated Value 0 0 4294967295 ICDC Integrated Value for Temperature Raise Band [1Count]
Make it 0 when performing ProCon Mid/End Setup.
* ICDC when A4 A/C 100% = 10000
Count O O
761-003 #C Temperature Raise ICDC Integrated Value 0 0 4294967295 ICDC Integrated Value for Temperature Raise Band [1Count]
Make it 0 when performing ProCon Mid/End Setup.
* ICDC when A4 A/C 100% = 10000
Count O O
761-004 #K Temperature Raise ICDC Integrated Value 0 0 4294967295 ICDC Integrated Value for Temperature Raise Band [1Count]
Make it 0 when performing ProCon Mid/End Setup.
* ICDC when A4 A/C 100% = 10000
Count O O
761-005 #Y Temperature Raise Band Deve Cycle 0 0 65535 No. of Deve Cycle for Temperature Raise Band
Make it 0 when performing ProCon Mid/End Setup.
0.1[Cycle] O O
761-006 #M Temperature Raise Band Deve Cycle 0 0 65535 No. of Deve Cycle for Temperature Raise Band
Make it 0 when performing ProCon Mid/End Setup.
0.1[Cycle] O O
761-007 #C Temperature Raise Band Deve Cycle 0 0 65535 No. of Deve Cycle for Temperature Raise Band
Make it 0 when performing ProCon Mid/End Setup.
0.1[Cycle] O O
761-008 #K Temperature Raise Band Deve Cycle 0 0 65535 No. of Deve Cycle for Temperature Raise Band
Make it 0 when performing ProCon Mid/End Setup.
0.1[Cycle] O O
761-009 DEVE Reverse Rotation PV Counter YMC 0 0 1000 DEVE Reverse Rotation PV Counter YMC PV O O
761-010 DEVE Reverse Rotation PV Counter K 0 0 1000 DEVE Reverse Rotation PV Counter YMC PV O O
761-011 Auger Mark Countermeasure Sub Motor PS63 Drive Time
(YMC)
0 0 3000000 Drive Time in Sub Motor 63mm/s (YMC)
Clear after driving for more than the given time with PS=126mm/s.
ms O O
761-012 Auger Mark Countermeasure Sub Motor PS63 Drive Time
(K)
0 0 3000000 Drive Time in Sub Motor 63mm/s (K)
Clear after driving for more than the given time with PS=126mm/s.
ms O O
761-013 Auger Mark Countermeasure Sub Motor PS126 Drive
Time (K)
0 0 3000000 Drive Time in Sub Motor 126mm/s (YMC) *Clear at the same time as
clearing of Auger Mark Countermeasure Sub Motor PS63 Drive Time
(YMC).
ms O O
761-014 Auger Mark Countermeasure Sub Motor PS126 Drive
Time (K)
0 0 3000000 Drive Time in Sub Motor 126mm/s (K) *Clear at the same time as
clearing of Auger Mark Countermeasure Sub Motor PS63 Drive Time
(YMC).
ms O O
761-023 #Y Deve Low A/C Band Deve Cycle 0 0 65535 No. of Deve Low A/C Band Deve Cycle 0.1[Cycle] O O
761-024 #M Deve Low A/C Band Deve Cycle 0 0 65535 No. of Deve Low A/C Band Deve Cycle 0.1[Cycle] O O
761-025 #C Deve Low A/C Band Deve Cycle 0 0 65535 No. of Deve Low A/C Band Deve Cycle 0.1[Cycle] O O
761-026 #K Deve Low A/C Band Deve Cycle 0 0 65535 No. of Deve Low A/C Band Deve Cycle 0.1[Cycle] O O
761-027 R/L Determination Job Counter BW 0 0 1000 Counts the no. of Job during Procon ADC Setup Interval. Times O O
761-028 R/L Determination Job Counter FC 0 0 1000 Counts the no. of Job during Procon ADC Setup Interval. Times O O