7.3 BSD
Chain1 Standby Power
ABCDEFGHJ
1
2
3
4
5
6
7-5
1.3 DC POWER GENERATION (2 OF 2)
j0bs730103
LVPS
PL18.3
DC POWER
GENERATION
1.1
1
STBY
+24VDC
1.2
POWER ON
ACH LV
POWER ON
ACN LV
STBY
+24VDC
RETURN
INTLK ON
+5VDC (1.6 C3)
DC COM
READY
POWER
ON SIGNAL
INTLK
+24VDC
10.2
ESS PWB
PL18.2
DC COM
STBY
+24VDC
J5C
3
2 4
ORN
VIO
J501
6
5
DRIVE PWB
PL18.2
ALL
J400
1
ALL
DC COM
2
INTLK
+24VDC
3
ORN
VIO
DC COM
INTLK
+24VDC
ALL
F3 INTLK
+24VDC
F3
ALL
F4 INTLK
+24VDC
F4
ALL
+24V ON
SIGNAL
ON/
OFF
SLEEP
+24VDC
ALL
+24VDC
F1
ALL
DC COM
NOTE: 1
・Short Protection (Over-current Protection)
If +5VDC output is shorted, it drops. If +24V output is shorted,
all the outputs are made to stop.
To restore them, repair the short, power off, allow 15 sec,
and then power on.
Over-voltage
+5VDC
+24VDC
+6~+9VDC
+26.7~32VDC
Output
・Over-voltage Protection
If one of the outputs reaches its listed voltage, all the outputs are
cut off. To restore them, power Output off, allow 15 sec, and then
power on.
POWER
ON
ACN LV
(1.1 G3)
POWER
ON
ACN LV