1.SC Codes
127
If they are defective, replace them. Turn the main power OFF and then ON.
6. Replace the main PCB.
SC506-23
Error Name
Vacuum Feed LCIT 2 Tray 1 Lowering Timeout
Pattern
B
Error Condition
When Vacuum Feed Banner Sheet Tray is Not Installed
ï‚· During tray initialization, the upper limit sensor 2 remains on after the tray bottom plate has been
lowered for a prescribed time)
ï‚· Upper limit sensor 2, lower limit sensor, and the paper height middle sensor fail to detect (tray
bottom plate is not lowered).
When Vacuum Feed Banner Sheet Tray is Installed
ï‚· During tray initialization, the upper limit sensor 2 remains on after the tray bottom plate has been
lowered for a prescribed time)
ï‚· Upper limit sensor 2, and the paper height middle sensor fail to detect (tray bottom plate is not
lowered).
Major Cause
When Vacuum Feed Banner Sheet Tray is Not Installed
ï‚· Power of downstream unit is not turned on.
ï‚· Lift motor is defective or not connected properly.
ï‚· Lower limit sensor is defective or not connected properly.
ï‚· Paper height middle sensor is defective or not connected properly.
ï‚· Harnesses are damaged.
ï‚· PCB is defective.
ï‚· Upper limit sensor 2 is defective or not connected properly.
When Vacuum Feed Banner Sheet Tray is Installed
ï‚· Power of downstream unit is not turned on.
ï‚· Lift motor is defective or not connected properly.
ï‚· Paper height middle sensor is defective or not connected properly.
ï‚· PCB is defective.
ï‚· Upper limit sensor 2 is defective or not connected properly.
ï‚· Harnesses are damaged.