1.SC Codes
483
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-51
Error Name
Perfect Binder: Internal temperature thermistor error
Pattern
B
Error Condition
Temperature was detected above 10°C three consecutive times (sampled every sec. for 1 min.).
Major Cause
ï‚· Internal temperature thermistor connector loose, broken, defective
ï‚· Thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-52
Error Name
Perfect Binder: Glue heater startup error 2
Pattern
B
Error Condition
The warm-up temperature was above the +-5°C target for the glue vat temperature. (Not detected
within 100 sec. after machine warm-up.)