1.SC Codes
567
then check if the SC recurs.
3. Check the harness.
If the harness between the stack tamper motor/stack tamper HP sensor and the sub board is
damaged or exposed, replace the harness. Turn the power OFF/ON, and then check if the SC
recurs.
4. Replace the components.
ï‚· Replace the stack tamper motor.
ï‚· Replace the stack tamper HP sensor.
ï‚· Replace the sub board.
SC756-34
Error Name
Ring Binder: Pre-Bind Jogger Clamp HP Error
Pattern
B
Error Condition
ï‚· The pre-bind jogger clamp moved from home position, but home position is detected even after a
specified time had passed. (The first time is reported as a jam. An SC is issued the second time
this occurs.)
ï‚· The pre-bind jogger clamp has moved to the home position, but home position is not be detected
within a specified time. (The first time is reported as a jam. An SC is issued the second time this
occurs.)
*First time jam: Pre-punch jogger jam (J343)
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Spine camp motor defective
ï‚· Connector disconnected
ï‚· Overload
ï‚· Clamp unit HP sensor defective
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the spine clamp motor/clamp HP Sensor and the sub board. (Check
all the connectors are completely connected.)
If the connector is not connected properly, reconnect the connector. Turn the power OFF/ON, and
then check if the SC recurs.