EasyManua.ls Logo

Ricoh Pro 8300S - LCT1: Overcurrent Protection Device Error (Vacuum Feed LCIT); Overcurrent Protection Device Error 8 (Bridge Unit); Sc761-67; Sc780-03

Ricoh Pro 8300S
963 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.SC Codes
580
Harness broken
Transport motor defective
Solution
1. Replace the transport motor.
2. Replace the harness.
3. Replace the bridge unit board.
SC761-67
Error Name
Overcurrent Protection Device Error 8 (Bridge Unit)
Pattern
D
Error Condition
The fuse blew on the PCB
Major Cause
Power of downstream unit is not off.
Bridge unit board defective
Harness broken
Entrance motor defective
Exit motor defective
Solution
1. Replace the entrance motor.
2. Replace the exit motor.
3. Replace the harness.
4. Replace the bridge unit board.
SC780-03
Error Name
LCT1: Overcurrent Protection Device Error (Vacuum Feed LCIT)
Pattern
B
Error Condition
The fuse on the PSU/PCB in LCT1 blew. (fuse blown signal “H (error)”)