1.SC Codes
41
Pattern
D
Error Condition
This error is detected when the black level is not within the prescribed value.
Major Cause
1. Connectors are not connected properly.
2. SBU is defective.
3. BiCU is defective.
4. Harness is defective.
Solution
1. Connectors not connected properly
Reconnect the following connectors:
SBU-BiCU harness (shielded cables/separate cables) connector
2. Replace the SBU board (lens block).
3. Replace the BiCU board.
4. Harness defective
Replace the harness between SBU-BiCU (shielded cables/separate cables).
SC142-00
Error Name
White Level Detection Error (Front)
Pattern
D
Error Condition
Error detection timing: during adjusting the gain control setting for scanner
This error is detected when the scan level (peak detection level) of the white plate is not within the
prescribed value when adjusting scanner gain.
Major Cause
1. Connectors are not connected properly.
2. White plate is dirty or defective.
3. Mirror, optics are defective.
4. LED boards are defective.
5. SBU is defective.
6. BiCU is defective.