1.SC Codes
219
4. Board defective
Replace the main board of Finisher SR5110/SR5120
* Before replacing the board, check if the SC occurs in the same way.
SC720-11 to 18
Error Name
ï‚· 720-11: Transport Motor 2 Error (Junction Gate Transport)
ï‚· 720-12: Transport Motor 3 Error (Horizontal Transport)
ï‚· 720-13: Transport Motor 4 Error (Registration)
ï‚· 720-14: Transport Motor 5 Error (Shift tray 1 Transport)
ï‚· 720-15: Transport Motor 6 Error (Pre-Stack)
ï‚· 720-16: Exit Motor 1 Error (Shift Tray 1 Exit)
ï‚· 720-17: Exit Motor 2 Error (Shift Tray 2 Exit)
ï‚· 720-18: Exit Motor 3 Error (Staple Tray 1 exit)
Pattern
ï‚· 720-11: D
ï‚· 720-12: D
ï‚· 720-13: D
ï‚· 720-14: B
ï‚· 720-15: B
ï‚· 720-16: B
ï‚· 720-17: B
ï‚· 720-18: B
Error Condition
DCM drive software detects a motor drive error. (The first four times are reported as jams. An SC is
issued when it is repeated five times.)
Major Cause
ï‚· Power of the downstream device is not turned on.
ï‚· Motor is defective
ï‚· Connector is not connected properly.
ï‚· Harness is damaged
ï‚· Motor is overloaded.
ï‚· Encoder is defective.
ï‚· Board is damaged.
*Corresponding motors:
ï‚· 720-11: JG transport motor <DCSM03>