1.SC Codes
362
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
ï‚· Check the remaining amount of glue pellets.
ï‚· Remove the clogged glue.
ï‚· Check the gluing unit.
SC751-14
Error Name
Perfect Binder: Glue High Limit Late Error
Pattern
D
Error Condition
Without glue application, and with the glue level above the lower limit, the glue level thermistor did not
detect the level of the glue at the upper limit, even after 12 glue pellets were supplied.
Major Cause
ï‚· Glue clogged, or glue supply defective
ï‚· Glue level thermistor connector loose, damaged, or defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
ï‚· Check the remaining amount of glue pellets.
ï‚· Remove the clogged glue.
ï‚· Check the gluing unit.
SC751-15
Error Name
Perfect Binder: Glue Lowering Level Error
Pattern
D