1.SC Codes
415
SC752-20
Error Name
Perfect Binder: Left Cover Guide Release Position Late Error
Pattern
D
Error Condition
During movement toward the left cover guide open position, the cover guide open sensor (left) did not
go ON after the cover guide motor (left) had operated long enough for 3000 ms of movement.
Major Cause
ï‚· Cover guide (left) open sensor defective
ï‚· Cover guide motor (left) defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover guide motor (left).
ï‚· Replace the Cover guide (left) open sensor.
ï‚· Replace the master control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC752-21
Error Name
Perfect Binder: Cover Guide (Right) HP Sensor Late Error
Pattern
D
Error Condition
During movement toward the HP sensor of the right cover path, the cover guide HP sensor (right) did
not go ON after the cover guide motor (right) had operated long enough for 3000 ms of movement.
Major Cause
ï‚· Cover guide (right) HP sensor defective
ï‚· Cover guide motor (right) defective
Solution
ï‚· Reconnect the connector.