1.SC Codes
427
SC752-40
Error Name
Perfect Binder: Main Grip Rotate Enable Position Sensor Lag Error
Pattern
D
Error Condition
While passing the signature, the MG rotate enable sensor did not go OFF, even though the signature
move motor had operated for 1450 ms.
Major Cause
ï‚· Signature move motor defective
ï‚· MG rotate enable sensor defective
ï‚· Connector harness loose, damaged, or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the signature move motor.
ï‚· Replace the MG rotate enable sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC752-41
Error Name
Perfect Binder: Signature Move HP Sensor Error
Pattern
D
Error Condition
The signature move HP sensor and signature move MG position sensor went on at the same time.
Major Cause
ï‚· Signature move HP sensor defective
ï‚· Signature MG position HP sensor defective
ï‚· Connector harness loose, damaged, or defective