1.SC Codes
319
Error Condition
Cutter control board could not communicate with the slave control board (communication alarm for over
5 sec.)
Major Cause
ï‚· Slave Control Board defective
ï‚· Cutter control board defective
ï‚· Connector loose, damaged, or defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the slave control board.
ï‚· Replace the cutter control board.
ï‚· Replace the harness.
SC750-15
Error Name
Perfect Binder: Master EEPROM Read Error
Pattern
D
Error Condition
Data written to the EEPROM does not match data read from the EEPROM
Major Cause
ï‚· EEPROM defective
Solution
ï‚· Replace the master control board EEPROM
ï‚· Replace the master control board.
SC750-16
Error Name
Perfect Binder: Master EEPROM Write Error
Pattern
D