1.SC Codes
495
Major Cause
ï‚· Cover horizontal registration sensor (S) connector loose, broken, defective
ï‚· Sensor defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover horizontal registration sensor (S).
ï‚· Replace the slave control board.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-71
Error Name
Perfect Binder: Cover horizontal registration sensor (L) adjustment low value error
Pattern
B
Error Condition
The cover horizontal registration sensor (L) A/D input value was higher than 3.2 to 3.54V, and the A/D
input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V.
Major Cause
ï‚· Cover horizontal registration sensor (L) connector loose, broken, defective
ï‚· Sensor defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover horizontal registration sensor (L).
ï‚· Replace the slave control board.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-72
Error Name
Perfect Binder: Signature exit sensor adjustment low value error