1.SC Codes
624
Pattern
D
Error Condition
An SC that is not controlled by the system occurred.
Major Cause
ï‚· SC for the previous model was used mistakenly, etc.
ï‚· Basically a software bug.
Solution
Turn the main power OFF/ON.
SC994-00
Error Name
Operation Panel Management Record Limit Reached
Pattern
C
Error Condition
Reached the limit for the operation panel screen configuration item records managed by the service
layer.
Major Cause
Too many application screens were opened on the operation panel.
Solution
Logging only
SC995-01
Error Name
CPM Setting Error
Pattern
D
Error Condition
Machine serial number (11 digits) is incorrect.