1.SC Codes
461
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-16
Error Name
Perfect Binder: Press plate late error
Pattern
B
Error Condition
ï‚· Edge press plate sensor did not go ON within 15 sec. of edge press release.
ï‚· The edge press plate motor stopped when the edge press plate HP sensor switched ON, but after
it stopped the HP sensor went OFF.
Major Cause
ï‚· Edge press plate motor connection loose, broken, defective
ï‚· Motor overloaded
ï‚· Motor defective
ï‚· Edge press plate HP sensor connection loose, broken, defective
ï‚· Sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the edge press plate motor.
ï‚· Replace the edge press plate HP sensor.
ï‚· Replace the cutter control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-17
Error Name
Perfect Binder: Press end sensor lag jam
Pattern
B
Error Condition
After the press plate released the signature and moved the prescribed distance, the press end sensor
did not go OFF.