1.SC Codes
560
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Motor defective (Side jogger motor)
ï‚· Connector disconnected
ï‚· Overload
ï‚· Home position sensor defective (Side jogger HP sensor)
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the side jogger motor/side jogger HP sensor and main board.
(Check that all the connectors are properly connected.)
If the connector is not connected properly, reconnect the connector. Turn the power OFF/ON, and
then check if the SC recurs.
3. Replace the components.
ï‚· If the side jogger motor does not operate, replace the motor.
ï‚· If the side jogger HP sensor does not react, replace the sensor.
ï‚· If the main board on the ring binder is defective, replace the board.
SC756-21
Error Name
Ring Binder: Pre-Punch Jogger Roller HP Error
Pattern
B
Error Condition
ï‚· The pre-punch jogger roller moved from home position, but home position is detected even after a
specified time had passed. (The first time is reported as a jam. An SC is issued the second time
this occurs.)
ï‚· The pre-punch jogger roller has moved to the home position, but home position is not be detected
within a specified time. (The first time is reported as a jam. An SC is issued the second time this
occurs.)
* The first time: Pre-punch jam (J334)
Major Cause
ï‚· Power of downstream unit not turned on.
ï‚· Motor defective (Punch pre roller lift motor)
ï‚· Connector disconnected