1.SC Codes
358
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
SC750-87
Error Name
Perfect Binder: Internal Temperature Thermostat Disconnect Error
Pattern
D
Error Condition
The A/D value of the internal temperature thermostat was detected to be below -20 degrees for 1 sec.
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
SC750-88
Error Name
Perfect Binder: Internal Temperature Thermostat Error
Pattern
D
Error Condition
Temperature was detected to be 10 degrees or more three consecutive times (sampled every sec. for 1
min.).