1.SC Codes
381
SC751-46
Error Name
Perfect Binder: Signature Thickness Sensor Maximum Value Error
Pattern
D
Error Condition
When the result of the signature thickness detection (A/D value) was adjusted, the maximum value
(25mm) was larger than the A/D value.
Major Cause
Sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Specify the signature thickness again.
ï‚· Replace the signature thickness sensor.
ï‚· Replace the master control board EEPROM
ï‚· Replace the slave control board.
ï‚· Replace the master control board.
ï‚· Replace the VR harness.
SC751-47
Error Name
Perfect Binder: Signature Signature Thickness Sensor Value Unstable Error
Pattern
D
Error Condition
The signature thickness reading did not change, even after the main grip unit opened and closed.
Major Cause
ï‚· Signature thickness sensor connector loose, damaged, or defective
ï‚· Sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Specify the signature thickness again.