1.SC Codes
572
Pattern
B
Error Condition
ï‚· The clamp moved from home position, but home position is detected even after a specified time
had passed. (The first time is reported as a jam. An SC is issued the second time this occurs.)
ï‚· The clamp has moved to the home position, but home position is not be detected within a specified
time. (The first time is reported as a jam. An SC is issued the second time this occurs.)
ï‚· *First time jam: 50/100 Clamp adjust motor jam (J346)
Major Cause
ï‚· Downstream unit off
ï‚· 50/100 clamp adjust motor defective
ï‚· Connector disconnected
ï‚· Overload
ï‚· Ring switch HP sensor defective
ï‚· Ring switch timing sensor defective
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the 50/100 clamp adjust motor/ring switch HP sensor and the sub
board. (Check all the connectors are completely connected.)
If the connector is disconnected, reconnect the connector. Turn the power OFF/ON, and then
check if the SC recurs.
3. Check the harness.
Check if the harness between the motor/sensor and the sub board is damaged or exposed. If so,
replace the harness. Turn the power OFF/ON, and then check if the SC recurs.
4. Replace the components.
ï‚· Replace the 50/100 clamp adjust motor
ï‚· Replace the ring switch HP sensor
ï‚· Replace the sub board.
SC756-45
Error Name
Ring Binder: Timing Sensor Interval Error
Pattern
B