1.SC Codes
202
SC673-10
Error Name
Operation Panel Flair Communication Error
Pattern
D
Error Condition
ï‚· Communication between the operation panel and main machine (flair communication) is not sent.
ï‚· SP setting (SP5-748-201) for Smart Operation Panel is not enabled.
Major Cause
The CATS module (controller) cannot notify a response to a notification from the monitoring service
module (operation panel).
Solution
1. Turn the main power OFF and then ON.
2. Set SP5-748-201 (OpePanel Setting: Cheetah Panel Connect Setting) to "1: Connect" if the value
is "0: Not connect".
SC682
Error Name
ï‚· 682-01: PCU: ID Chip Communication Error (K_Invalid Device ID)
ï‚· 682-06: PCU: ID Chip Communication Error (K_Channel error (e.g. bus disconnection))
ï‚· 682-11: PCU: ID Chip Communication Error (K_Device Error (No ID chip))
ï‚· 682-16: PCU: ID Chip Communication Error (K_Communication aborted (error during
communication))
ï‚· 682-21: PCU: ID Chip Communication Error (K_Communication timeout)
ï‚· 682-26: PCU: ID Chip Communication Error (K_Device stopped (logically stopped))
ï‚· 682-31: PCU: ID Chip Communication Error (K_Requested buffer full)
ï‚· 682-36: PCU: ID Chip Communication Error (K_No error code)
Pattern
D
Error Condition
CPU of the BiCU detects communication error with the TD sensor.
Major Cause
1. PCU drawer is not set properly.