1.SC Codes
317
Solution
ï‚· Reconnect the connector.
ï‚· Replace the master control board.
ï‚· Replace the slave control board.
ï‚· Replace the harness.
SC750-11
Error Name
Perfect Binder: Master-to-Slave Communication Error 2
Pattern
D
Error Condition
Communication alarm issued when slave control board could not communicate with the master control
board for over 5 sec.
Major Cause
ï‚· Master control board is defective.
ï‚· Slave Control Board is defective
ï‚· Connector loose, damaged, or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the master control board.
ï‚· Replace the slave control board.
ï‚· Replace the harness.
SC750-12
Error Name
Perfect Binder: Master-to-Relay Board Communication Error
Pattern
D
Error Condition
ï‚· IPU not "READY"
ï‚· IPU occupancy not obtained
ï‚· IPU detected an error