1.SC Codes
327
Error Condition
The grip HP sensor did not OFF after grip unit moved 20 mm.
Major Cause
ï‚· Grip motor defective
ï‚· Grip HP sensor defective
ï‚· There is overload
ï‚· Sensor flag defective
ï‚· Connector damaged or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the grip motor.
ï‚· Replace the grip HP sensor.
ï‚· Replace the cutter control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC750-38
Error Name
Perfect Binder: Grip HP Sensor Late Error
Pattern
D
Error Condition
The HP sensor does not go ON after the grip unit was released and moved 76 mm.
Major Cause
ï‚· Grip motor defective
ï‚· Grip HP sensor defective
ï‚· There is overload
ï‚· Sensor flag defective
ï‚· Connector damaged or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the grip motor.
ï‚· Replace the grip HP sensor.
ï‚· Replace the cutter control board.