1.SC Codes
369
Major Cause
ï‚· Timing sensor connector loose, damaged, or defective
ï‚· Sensor defective
ï‚· Master control board disconnected, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the timing sensor.
ï‚· Replace the cutter control board.
ï‚· Replace the sensor harness.
SC751-26
Error Name
Perfect Binder: Cover Registration Sensor Adjustment Low Value Error
Pattern
D
Error Condition
The cover registration sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not
enter the range 3.0 to 3.5V, even after the cover registration sensor D/A output value output was
lowered 0.1V.
Major Cause
ï‚· Cover registration sensor connector loose, damaged, or defective
ï‚· Sensor defective
ï‚· Master control board disconnected, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover registration sensor.
ï‚· Replace the master control board.
ï‚· Replace the sensor harness.
SC751-27
Error Name
Perfect Binder: Cover Horizontal Registration Sensor (S) Adjustment Low Value Error