1.SC Codes
447
SC752-74
Error Name
Perfect Binder: Cover Interposer Tray EEPROM Write Error
Pattern
D
Error Condition
When data was written to EEPROM, the write data and read data did not match.
Major Cause
ï‚· EEPROM defective
ï‚· EEPROM not installed, or not installed correctly
Solution
ï‚· Replace the EEPROM on the interposer control board.
ï‚· Replace the interposer control board.
SC752-75
Error Name
Perfect Binder: Drive Switch Motor Error (Down to Up)
Pattern
D
Error Condition
The rack where the drive gear is mounted did not retract from the drive switch sensor after the drive
switch motor operated for 3 sec.
Major Cause
ï‚· Drive switch motor defective
ï‚· Drive switch sensor defective
ï‚· Connector loose, damaged, or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the drive switch motor.
ï‚· Replace the drive switch sensor.
ï‚· Replace the inserter control board.