1.SC Codes
463
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-19
Error Name
Perfect Binder: Slide HP sensor lag error
Pattern
B
Error Condition
When the slide was raised, the slide HP sensor did not go OFF after it moved 180 mm.
Major Cause
ï‚· Slide motor connection loose, broken, defective
ï‚· Motor overloaded, defective
ï‚· Slide HP sensor connection loose, broken, defective
ï‚· Sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the slide motor.
ï‚· Replace the slide HP sensor.
ï‚· Replace the cutter control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
ï‚· Clear the signature jam.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-20
Error Name
Perfect Binder: Slide HP sensor late error
Pattern
B
Error Condition
The slide HP sensor did not go ON after the slide was lowered and had enough time to move 180 mm.