1.SC Codes
482
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-49
Error Name
Perfect Binder: Internal temperature thermistor error
Pattern
B
Error Condition
The A/D value of the internal temperature thermostat was detected above 80 degrees for 1 sec.
Major Cause
ï‚· Internal temperature thermistor connector loose, broken, defective
ï‚· Thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-50
Error Name
Perfect Binder: Internal temperature thermostat disconnect error
Pattern
B
Error Condition
The A/D value of the internal temperature thermostat was detected below -20 degrees for 1 sec.
Major Cause
ï‚· Internal temperature thermistor connector loose, broken, defective
ï‚· Thermistor defective
ï‚· Slave board defective