326
ï‚· 750-34: Perfect Binder: Signature Fan 1 (Rear) Lock Error
ï‚· 750-35: Perfect Binder: Glue Supply Fan (High) Lock Error
ï‚· 750-36: Perfect Binder: Glue Supply Fan (low) Lock Error
Pattern
D
Error Condition
There was a lock signal within 12 sec., and the signal was again detected after a re-try.
This SC occurs when the lock signal is detected after 12 sec.
Major Cause
ï‚· The fan overloaded or defective
ï‚· Slave control board defective
Target fan:
ï‚· 750-27: Spine plate fan (front)
ï‚· 750-28: Spine plate lower fan (right)
ï‚· 750-29: Spine plate upper fan (front)
ï‚· 750-30: Spine plate upper fan (right)
ï‚· 750-31: Signature fan 2 (front)
ï‚· 750-32: Signature fan 2 (rear)
ï‚· 750-33: Signature fan 1 (front)
ï‚· 750-34: Signature fan 1 (rear)
ï‚· 750-35: Glue supply fan (high)
ï‚· 750-36: Glue supply fan L
Solution
ï‚· Reconnect the connector.
ï‚· Replace the fan.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.