1.SC Codes
321
Error Condition
ï‚· No response to the specified command within the specified time.
ï‚· There was an overflow in memory where information for paper feed is stored (master control board
detection).
Major Cause
ï‚· Error in communication from the inserter
ï‚· Connector loose, damaged, or defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the master control board.
ï‚· Replace the inserter board.
ï‚· Replace the harness.
SC750-19
Error Name
Perfect Binder: Software Matching Error
Pattern
D
Error Condition
The IDs of the master, slave, cutter, inserter, and relay sofware do not match.
Major Cause
Software write failure
Solution
Download the software.
SC750-20
Error Name
Perfect Binder: 24V Check Signal Error 1
Pattern
D
Error Condition
The 24V1 monitor signal of the master control board did not go off even though the front door switch