1.SC Codes
371
ï‚· Replace the sensor harness.
SC751-29
Error Name
Perfect Binder: Signature Exit Sensor Adjustment Low Value Error
Pattern
D
Error Condition
The signature exit sensor A/D input value was higher than 3.2 to 3.54V, the A/D input value did not
enter the range 3.2 to 3.54V, even after the sensor output value output was lowered 0.04V.
Major Cause
ï‚· Signature exit sensor connector loose, damaged, or defective
ï‚· Sensor defective
ï‚· Slave control board disconnected, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the signature exit sensor.
ï‚· Replace the slave control board.
ï‚· Replace the sensor harness.
SC751-30
Error Name
Perfect Binder: LE Detect Sensor Adjustment Low Value Error
Pattern
D
Error Condition
The LE detect sensor A/D input value was higher than 3.2 to 3.54V, and the sensor A/D input value did
not enter the range 3.2 to 3.54V, even after the sensor output value was lowered 0.04V.
Major Cause
ï‚· LE detect sensor connector loose, damaged, or defective
ï‚· Sensor defective
ï‚· Slave control board disconnected, defective