1.SC Codes
626
Solution
1. Re-install the controller board.
Check the connection between the BiCU and the controller board.
2. Replace with the controller board for this model (machine).
SC995-04
Error Name
CPM Setting Error
Pattern
D
Error Condition
Machine serial number (11 digits) is incorrect.
Major Cause
ï‚· Multiple component replacement mistakes (controller board / NVRAM / BiCU)
ï‚· A number of components are defective at the same time (controller board / NVRAM / BiCU)
Solution
1. Re-install the controller board, NVRAM and BiCU again. Use the previous NVRAM (the one used
before replacement)
2. Replace the controller board, NVRAM and BiCU again.
SC997-00
Error Name
Application Function Selection Error
Pattern
D
Error Condition
Application does not run when it is selected using the function key on the operation panel (no response,
or aborted).
Major Cause
Software bug (mainly of the application)
Solution
1. Check the optional RAM, DIMM, boards required by the application program.