1.SC Codes
61
ï‚· There is abnormal increase in development driving unit torque.
ï‚· The development motor (BLM8) has failed.
ï‚· The harness is damaged.
ï‚· IOB is defective.
Solution
1. Check overload on the development unit (check if there are obstacles, bearing lock, or adherence).
2. Check whether the development motor harness connector and IOB harness connector are properly
connected.
3. Check overload on the development driving unit (check if there are obstacles or the belt/gear is
broken).
4. Replace the development motor (BLM8).
5. Replace the development motor harness (if the harness is damaged or there is pressure contact
failure).
6. Replace the IOB.
SC332-10
Error Name
Toner Supply Motor Error 1, 2: Bottle
Pattern
D
Error Condition
The toner bottle did not rotate correctly when supplying toner.
Major Cause
ï‚· Bottle cap is broken.
ï‚· There is large rotational load torque due to the toner bottle being set incorrectly.
ï‚· Connector not set properly.
ï‚· Harness damaged.
ï‚· Bottle cap motor (right) (BM6), bottle cap motor (left) (BM8) are defective.
Solution
1. Check if the bottle cap is broken.
Check whether the bottle cap can be released by executing "Bottle1OPEN/CLOSE" (SP2-780-001)
and "Bottle2OPEN/CLOSE" (SP2-780-002).
If not, the bottle cap is broken or the bottle cap motors are defective.
Replace the bottle cap or bottle motors.
Bottle Cap Motors (Right): BM7