1.SC Codes
324
Solution
ï‚· Reconnect the connector.
ï‚· Replace the front door L/RSW
ï‚· Replace the slave control board.
ï‚· Replace the sensor harness.
SC750-24
Error Name
Perfect Binder: Power Supply Fan (Right) Lock Error
Pattern
D
Error Condition
When the right power supply fan is rotating, there was a lock signal within 12 sec., and the signal was
again detected after a re-try.
This SC occurs when the lock signal is detected after 12 sec.
Major Cause
ï‚· Right power supply fan is overloaded or defective.
ï‚· Slave control board is defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the right power supply fan
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
SC750-25
Error Name
Perfect Binder: Power Supply Fan (Center) Lock Error
Pattern
D
Error Condition
When the center power supply fan is rotating, there was a lock signal within 12 sec., and the signal was
again detected after a re-try.
This SC occurs when the lock signal is detected after 12 sec.