1.SC Codes
545
ï‚· Connector or harness loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the main grip motor (R).
ï‚· Replace the main grip close sensor (R).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-66
Error Name
Perfect Binder: Main Grip Motor (R) Rotation Error
Pattern
B
Error Condition
At the start of the main grip open operation, the MG encoder sensor (R) was not detected on/off, even
after the MG motor (R) had operated for 200 ms.
Major Cause
ï‚· Main grip motor (R) defective
ï‚· Main grip encoder sensor (R) defective
ï‚· Connector or harness loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the main grip motor (R).
ï‚· Replace the main grip encoder sensor (R).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.