1.SC Codes
352
Error Condition
The book door sensor is OFF with the book door locked.
Major Cause
ï‚· Book door lock solenoid defective
ï‚· Book door sensor defective
ï‚· Sensor disconnected
Solution
ï‚· Reconnect the connector.
ï‚· Replace the book door lock solenoid.
ï‚· Replace the book door sensor.
ï‚· Replace the cutter control board.
ï‚· Replace the SOL harness.
ï‚· Replace the sensor harness.
SC750-76
Error Name
Perfect Binder: Glue Heater Error
Pattern
D
Error Condition
The glue heater thermistor detected higher that 200 degrees for more than 1 sec.
Major Cause
ï‚· Glue temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC750-77
Error Name
Perfect Binder: Electrical Short in Gluing Unit